📋 核心要点

  1. 现有传感器方法在电力线路与潜在威胁之间的距离测量中面临准确性与成本的平衡挑战。
  2. ElectricSight系统通过结合实时图像与环境点云先验,实现了低成本的3D距离测量与监测。
  3. 实验结果显示,ElectricSight的距离测量平均准确度为1.08米,预警准确度高达92%。

📝 摘要(中文)

保护电力传输线路免受潜在危险的关键任务之一是准确测量电力线路与潜在威胁(如大型起重机)之间的距离。现有的传感器方法在距离测量的准确性与成本之间难以平衡。为此,本文提出了ElectricSight系统,旨在实现电力传输线路的3D距离测量与监测。该系统的创新之处在于其整体框架和单目深度估计方法,通过实时图像与环境点云先验结合,实现了经济高效且精确的3D距离测量。实验结果表明,ElectricSight在距离测量中平均准确度为1.08米,预警准确度达到92%。

🔬 方法详解

问题定义:本文旨在解决电力传输线路与潜在威胁之间的3D距离测量问题。现有方法如摄像头因缺乏深度信息而难以提供准确的3D距离,而高成本的3D激光设备又不适合大规模部署。

核心思路:ElectricSight系统通过单目深度估计方法,结合环境点云数据与实时图像,提供了一种经济高效的3D距离测量方案。这样的设计使得系统在保持成本低廉的同时,提升了测量的准确性和可靠性。

技术框架:ElectricSight的整体架构包括实时图像采集、单目深度估计、环境点云数据融合及距离计算模块。系统通过这些模块的协同工作,实现了对电力线路周围环境的实时监测。

关键创新:本研究的主要创新在于将单目深度估计与环境点云数据相结合,显著提高了3D距离测量的准确性。这一方法与传统的基于激光或多摄像头的测量方式相比,具有更低的成本和更高的灵活性。

关键设计:在系统设计中,采用了特定的损失函数来优化深度估计的准确性,并利用卷积神经网络(CNN)结构进行图像处理。关键参数的设置经过多次实验验证,以确保系统在不同环境下的稳定性和可靠性。

📊 实验亮点

实验结果表明,ElectricSight在距离测量中平均准确度为1.08米,预警准确度高达92%。这一性能显著优于传统方法,展示了该系统在实际应用中的有效性与可靠性。

🎯 应用场景

ElectricSight系统具有广泛的应用潜力,尤其在电力行业的安全监测中。通过实时监测电力线路周围的潜在威胁,该系统能够有效预防事故发生,提升电力传输的安全性。此外,该技术还可扩展至其他领域,如建筑工地的安全监测和无人机的障碍物检测等。

📄 摘要(原文)

Protecting power transmission lines from potential hazards involves critical tasks, one of which is the accurate measurement of distances between power lines and potential threats, such as large cranes. The challenge with this task is that the current sensor-based methods face challenges in balancing accuracy and cost in distance measurement. A common practice is to install cameras on transmission towers, which, however, struggle to measure true 3D distances due to the lack of depth information. Although 3D lasers can provide accurate depth data, their high cost makes large-scale deployment impractical. To address this challenge, we present ElectricSight, a system designed for 3D distance measurement and monitoring of potential hazards to power transmission lines. This work's key innovations lie in both the overall system framework and a monocular depth estimation method. Specifically, the system framework combines real-time images with environmental point cloud priors, enabling cost-effective and precise 3D distance measurements. As a core component of the system, the monocular depth estimation method enhances the performance by integrating 3D point cloud data into image-based estimates, improving both the accuracy and reliability of the system. To assess ElectricSight's performance, we conducted tests with data from a real-world power transmission scenario. The experimental results demonstrate that ElectricSight achieves an average accuracy of 1.08 m for distance measurements and an early warning accuracy of 92%.